Telephone Entry Systems

Telephone Entry Systems

Aegis 7000 Series by Pach & Company

Aegis 7000 Series by Pach & Company

Electronic Features

Hands Free Multi Tenant Telephone Access Control Systems from 25 to 250 tenants and 25 to 250 4-digit personal access codes.

Programming local via system’s keypad or remote via a touch-tone phone.

Optional Radio Receiver and transmitter.

Remote Access press 9.

Local Access via 4-digit keypad entry code or optional radio transmitter.

Backlit Single Line Liquid Crystal Display (LCD) with Electronic Directory.

Postal Lock ready.

Transfer call to voice mail or extension manually. User must press the voice mail or extension number on the system's keypad to access it.

Programmable Talk Time 10 - 180 seconds, extendable for another cycle by pressing #.

Programmable relay output contact 01 - 98 seconds.

Manual unlock timer (01 hour-98 hours).

Recess Keypad w/ Built-in night light.

Available in Brushed Stainless Steel faceplate and Polished Brass.

Surface and full-flush mount, outdoor or indoor.

GENERAL SPECIFICATIONS

POWER INPUT: 12VAC/40VA (supplied) or 12VDC/40VA (output reading must be 13.5 - 14.5 VDC)
CURRENT CONSUMPTION: 500mA idle, 700mA operating
EMERGENCY BATTERY: Built-in charging circuit for 12VDC/4Ahr rechargeable battery (battery is not supplied)
OPERATING ENVIRONMENT: 32°F to 140°F. Humidity 0%-95% noncondensing Heater is required if the temperature is below 32°F
MEMORY: EEPROM (non-volatile)

Aegis 8000 Series by Pach & Company

Aegis 8000 Series by Pach & Company

Electronic Features

Hands Free System from 25 - 250 tenants and 25 - 250 codes.

On site programming via system’s keypad or remote dial-up programming via Pach and Company Management Software (Windows 95, 98, 2000,Me and XP compatible).

Optional Radio Receiver and transmitter.

Programmable DTMF (1-9) tone for remote Access.

Programmable relay output contact 04-98 seconds.

Built-in manual timer to unlock/lock door (not 24/7 automatic timer).

Two on board relays.

Programmable Talk Time 10 - 180 seconds, extendable for another cycle by pressing #.

Local Access keypad entry code or radio frequency transmitter.

600 event recording buffer.

Electronic Directory Single Line Liquid Crystal Display (LCD) with backlit.

Recess Keypad w/ Built-in night light.

Support PBX and Voice Mail.

Postal Lock ready.

Surface and full-flush Mount, outdoor or indoor.

Brushed Stainless Steel faceplate.

GENERAL SPECIFICATIONS

POWER INPUT: 12VAC/40VA (supplied) or 12VDC/40VA (output reading must be 13.5 - 14.5 VDC)
CURRENT CONSUMPTION: 500mA idle, 700mA operating
EMERGENCY BATTERY: Built-in charging circuit for 12VDC/4Ahr rechargeable battery (battery is not supplied)
OPERATING ENVIRONMENT: 32°F to 140°F. Humidity 0%-95% noncondensing Heater is required if the temperature is below 32°F
ELECTRONIC DIRECTORY: 1x16 Backlit Liquid Crystal Display (LCD)
DIALING: Tone

Aegis 9000 Series by Pach & Company

Aegis 9000 Series by Pach & Company

Electronic Features

Hands Free System from 25 - 1000 tenants and 200 - 1000 restricted or non-restricted keypad access codes, cards or transmitters.

Optional 26-Bit Wiegand Card Reader and Radio Reader.

On site programming via system’s keypad or RS232 or dial-up remote programming via Pach and Company Software (Windows 95, 98, 2000, Me, and XP compatible).

Programmable DTMF (1-9) tone for remote Access.

Local Access keypad access code, card, keypad + card or transmitter.

1200 event transactions buffer.

Postal Lock ready.

Backlit Two Lines Liquid Crystal Display (LCD) with Electronic Directory.

Support PBX and Voice Mail.

Door Sensor Input.

Built-in Modem, RS232 and RS485.

Interface with Pach and Company Satellite Card Reader (SCR9), Satellite Keypad (SK9) and RS-485 Wiegand Reader Controller Module (AWCRM). Maximum of 32 devices.

10-Time Zones, 10-Door Timers (auto unlock schedules), 16-Holidays.

Manual Unlock/lock timer 01- 98 hours.

Programmable Talk Time 10 - 240 seconds, extendable to an other cycle by pressing #.

Programmable relay output contact 04 - 99 seconds.

Programmable second relay as Door Control, Shunt, Alarm Timer or CCTV Switch.

Alarm alert beeps and calling the security guard if invalid code has been entered a specific number of time.

Surface and Full--flush Mount, outdoor or indoor.

GENERAL SPECIFICATIONS

POWER INPUT: 12VAC/40VA (supplied) or 12VDC/40VA (output reading must be 13.5 - 14.5 VDC).
CURRENT CONSUMPTION: 700mA idle, 900mA operating.
EMERGENCY BATTERY: Built-in charging circuit for 12VDC/4Ahr rechargeable battery (battery is not supplied).
OPERATING ENVIRONMENT: 32°F to 140°F Humidity 0%-95% noncondensing. Heater is required if the temperature is below 32°F.
ELECTRONIC DIRECTORY: 2x16 Backlit Liquid Crystal Display (LCD)
DIALING: Tone
NIGHT LIGHT: Super Bright Light Emitting Diode (LED)
MEMORY: EEPROM (non-volatile)
CLOCK BATTERY BACKUP: Ni-Cd 3.6V 60mAh
COMMUNICATION: 1200 Baud Modem, RS-485 and RS-232
CONSTRUCTION: 16 Gauge Cold Rolled Steel back box with enamel finished and Brushed Stainless Steel Faceplate
MOUNTING: Surface and full-flush

Commercial Telephone Entry System - One Door Model AE-100

Commercial Telephone Entry System - One Door Model AE-100

Electronic Features

The Model AE-100 Commercial Telephone Entry System - One Door is designed for use as a primary access control device for apartments, condominiums, and offices with up to 125 residents.

The system can be used in a lobby or outside. Surface, recessed, and pedestal mounting options are supported. The system utilizes hands-free, full duplex telephone communications between visitors and residents for granting access.

Housed in a locked, rugged stainless steel faced enclosure, the AE-100 features a lighted 12-key telephone style keypad and four operation buttons all with bright, easy-to-see graphics. The backlit two-line directory LCD display scrolls a programmable welcome message and shows the directory Names and Directory Codes.

The system contains a built-in microphone, tamper resistant speaker, and a TTY connector for the hearing impaired. The heavy duty access relay can control electric door strikes, magnetic locks, door & gate operators, or barrier gates.

Multi-lingual display programming prompts and voice help is available with a choice of English, Spanish, French-Canadian, or Portuguese language selection for the system. The system can be programmed locally using the keypad, or remotely with a touch tone telephone.

Up to four AE-100 units can be connected to the same dedicated telephone line to form a simple network. Connecting multiple units allows transferring programming data (either the directory entries only or the entire memory’s contents) from the "master" unit to the other sub-units.

Optional features that the AE-100 supports are provisions for postal lock and color CCTV camera installation (Model CCM-1).

The AE-100 is powered from a 16 VAC plug-in transformer and supports an internal rechargeable 1.2 amp/hour backup battery (not included). The battery charging circuit will support an external backup battery with up to 7 amp/hour capacity.

GENERAL SPECIFICATIONS

  • Applications include small apartment buildings, condominiums, or gated communities
  • Many installation choices: surface, recessed, gooseneck
  • Stainless steel front panel
  • Telephone style keypad with lighting
  • Accepts a total of 125 directory listings or stand-alone entry codes
  • TTY jack for connection to text communication devices for the hearing impaired
  • Simple network capability with up to four units
  • Installer friendly with two programming methods available
  • Two-line-16-character LCD display
  • Removable terminal blocks
  • Programmable through the unit's keypad or over the telephone
  • Form "C" access relay rated at 10 amps AC and 7 amps DC @ 30 volts
  • Load shed circuitry protects backup battery
  • Supports optional color CCTV camera and postal lock
  • Optional trim-ring (Model TR-100) for recessed mounting
  • 9.75" W x 11.75" H x 3.5" D
  • Order number: ACP00937
Commercial Telephone Entry System - Two Doors Model AE-500

Commercial Telephone Entry System - Two Doors Model AE-500

Electronic Features

The Model AE-500 Commercial Telephone Entry System - Two Doors is designed for use as a primary access control device for gated communities, parking garages, office buildings, apartments, dormitories, hotels/motels, commercial buildings and recreational facilities with up to 250 residents or users.

Housed in a locked, rugged stainless steel faced enclosure, the AE-500 features a side-lit 12-key telephone style keypad with bright, easy-to-read graphics, a backlit two-line directory display with a programmable welcome message, a built-in microphone, speaker, and provision for an optional color CCTV camera.

The two relay output channels can be programmed to control electric door strikes, magnetic locks, door & gate operators, or barrier gates.

The system utilizes hands-free, full duplex telephone communications between visitors and residents for granting access.

The system can be programmed locally using the keypad, remotely with a touch tone telephone, or remotely using a computer equipped with a modem and a web browser.

GENERAL SPECIFICATIONS

  • Economically priced
  • Stainless steel front panel
  • Telephone style keypad with surround lighting
  • Up to 250 user capacity
  • Accepts up to 500 entry codes
  • Built-in RF receiver
  • Up to 500 block coded or 500 individually enrolled transmitters
  • Two-line-16-character LCD display
  • Many installation choices: surface, recessed, gooseneck
  • Built-in modem for remote programming
  • Multiple programming methods: from keypad, from touchtone telephone, from web browser
  • Two configurable output relays
  • Applications include apartment buildings, condominiums, dorms, hospitals
  • Optional color CCTV camera
  • RF frequency: 318 MHz
DoorKing 1802-EPD Telephone Entry

DoorKing 1802-EPD Telephone Entry

Electronic Features

1802-EPD (Electronic Programmable Directory) are ideal telephone entry systems that are loaded with features and are suited for applications that have limited space and can be used in residential as well as commercial applications. The 1802 is designed for applications that do not require a directory, or in applications where a separate directory exist, while the 1802-EPD includes a built-in electronic directory. Visitors are easily identified by voice communication and can be granted or denied access directly from a touch-tone telephone.

The 1802-EPD are available in two distinct styles: Surface mount and flush mount.

Programmable directory codes (1-4 digits)
10 and 11-digit dialing capability
Two special inputs can be programmed for relay activation or to dial out a preprogrammed phone number
5-digit entry codes for special needs
LED lighted keypad
Built-in time clock
Hold open time zones
Entry code time zones
"Flash" entry codes
Built-in postal lock provision
1802 includes programming display
1802-EPD includes directory display

GENERAL SPECIFICATIONS

1802 stores up to 1000 telephone numbers
1802-EPD stores up to 100 telephone numbers and names
EEPROM Memory
Full duplex commnication
4-digit entry codes; same number as memory ordered
Six, 5-digit entry codes
15 area codes
16 VAC, 20 VA (250 ma) power transformer provided

DoorKing 1808 Telephone Entry

DoorKing 1808 Telephone Entry

Electronic Features

The model 1808 is a small compact telephone entry system that is loaded with features. The distinctive styling of the 1808 makes it ideal for small residential or commercial applications. And, by adding the optional built in directory, the 1808 is ideal for small multi-home gated community applications. The 1808 is available in surface mount style only. Visitors are identified by voice communication via the telephone. Access is granted by pressing "9" on your touch tone telephone, or access can be denied by simply hanging up. The 1808 is available with or without a small, built-in directory.

Programmable directory codes (1-4 digits)
10 and 11-digit dialing capability
Two special inputs can be programmed for relay activation or to dial out a preprogrammed phone number
5-digit entry codes for special needs
LED lighted keypad
Built-in time clock
Hold open time zones
Entry code time zones
"Flash" entry codes

GENERAL SPECIFICATIONS

Stores up to 1000 telephone numbers
EEPROM Memory
Full duplex commnication
4-digit entry codes; same number as memory ordered
Six, 5-digit entry codes
10 area codes
16 VAC, 20 VA (250 ma) power transformer provided
Ringer equivalence: 0.0 A
Jack type: RJ11C or W
FCC (US): DUF6VT-12874-OT-0
DOC (CAN): 1736 4507 A
Complies with UL 294; ETL Listed
Surface mount dimensions: 7.375"H x 11"W x 6.375"D

DoorKing 1810 Telephone Entry

DoorKing 1810 Telephone Entry

Electronic Features

With its built-in lighted directory, the Model 1810 is a complete self-contained telephone entry system that is ideal for small to medium sized apartment buildings, gated communities, condominiums, office buildings, factories and industrial sites. Managers can easily create and change the directory as needed with a word processing program (templates are available from DoorKing). The 1810 is available in both surface and flush mount styles. Visitors are identified by voice communication via the telephone. Access is granted by pressing "9" on your touch tone telephone, or access can be denied by simply hanging up.

The 1810 is available in two distinct styles: Surface mount and flush mount. Contact your professional DKS system installer for more information about this and other DKS products.

Programmable directory codes (1-4 digits)
10 and 11-digit dialing capability
Two special inputs can be programmed for relay activation or to dial out a preprogrammed phone number
5-digit entry codes for special needs
Built-in LED lighted directory
LED lighted keypad
Built-in time clock
Hold open time zones
Entry code time zones
"Flash" entry codes
Built-in postal lock provision
Programming display

GENERAL SPECIFICATIONS

Stores up to 1000 telephone numbers.
EEPROM Memory.
Full duplex commnication.
4-digit entry codes; same number as memory ordered.
Six, 5-digit entry codes.
10 area codes.
16 VAC, 20 VA (250 ma) power transformer provided.
Ringer equivalence: 0.0 A.
Jack type: RJ11C or W.
FCC (US): DUF6VT-12874-OT-0
DOC (CAN): 1736 4507 A
Complies with UL 294; ETL Listed.
Surface mount dimensions: 13"H x 11.25"W x 4.75"D.
Flush mount dimensions: 13.25"H x 12"W x 3"D

DoorKing 1812 Residential Telephone Entry System

DoorKing 1812 Residential Telephone Entry System

Electronic Features

The model 1812 is a unique telephone intercom system that allows homeowners to use their telephone as an intercom to speak to a guest at a front door or gate without the necessity to pay for an additional telephone line at their home. With its "intercom mode" programming feature, the 1812 can also be connected to a PBX or KSU type system, making it ideal for small businesses to control access through a single door or gate. Visitors are easily identified by voice communication and can be granted or denied access directly from a touch-tone telephone. The 1812 is available in both surface and flush mount designs and includes the DKS auto-programming software for Windows, allowing homeowners to program the system right from their home computer.

The 1812 is available in three distinct styles: Surface mount, Flush mount and Wall mount.

GENERAL SPECIFICATIONS

  • PC Programmable.
  • Distinctive double ring identifies visitor calls from regular calls.
  • Call waiting.
  • Call forwarding.
  • 3 preprogrammed call out telephone numbers.
  • "Do Not Disturb" time zone.
  • Hold open time zones.
  • Built-in time clock.
  • Entry code time zones.
  • "Flash" entry code.
  • LED lighted keypad.
  • 2 relays for door/gate control.

SPECIFICATIONS:

  • Connects in series with the residential phone line. By-pass switch provided
  • EEPROM Memory
  • Stores up to 3 call forwarding numbers
  • Full duplex commnication
  • 50, 4-digit entry codes
  • 24 VAC, 20 VA (250 ma) power transformer provided
  • FCC (US): DUF6VT-12874-OT-0
  • DOC (CAN): 1736 4507 A
  • Complies with UL 294; ETL Listed
  • Surface mount dimensions: 6.25"H x 10"W x 5.25"D
  • Flush mount dimensions: 9.25"H x 12"W x 4.5"D
  • Wall mount dimensions: 7.325"H x 10.75"W x 3.5"D

OPTIONS FOR THIS MODEL:

  • Surface, flush or wall mount - specify which.
  • Stainless steel or gold plated housing (surface mount only).
  • Gold plated faceplate - Flush or surface mount units only.

ACCESSORIES AVAILABLE FOR THIS MODEL:

  • Heater kit (recommended when temperatures routinely fall below 10F / -12C)
  • Mounting post
  • Auxiliary keypad for entry codes
  • Surge suppressors
DoorKing 1835 - PC Programmable

DoorKing 1835 - PC Programmable

Electronic Features

The Model 1835 is an ideal telephone entry system suited for apartment and gated community applications as well as office buildings and industrial sites that have a separate access control system, or require telephone entry only. The single-line LCD display features big 1/2-inch characters for easy viewing and your personalized message scrolls across the screen from right to left when the system is not in use. Our unique "One Touch" CALL button makes this system one of the easiest to use on the market today! The built-in electronic directory, easy to use Remote Account Manager programming software, card reader interface and expandability options make this unit an ideal choice for those applications with a large number of system users and entry locations. Up to 16 card readers can be interfaced with the 1835 to provide access control. Additionally, our elevator control module restricts which floors a guest or system users have access to, making it an ideal system for high rise buildings. For additional security, the 1835 allows you to monitor activity AS IT HAPPENS on your computer display (requires RS-232 connection), and with our anti-pass back memory, you can enable a TRUE anti-pass back system in one of three different configurations; passive, active and trap.

The 1835 is available in three distinct styles: Surface mount, Flush mount and Wall mount

PC Programmable via the internet (using DKS server connection) modem or RS-232. Remote Account Manager and Transaction Analysis software included
Large easy to use A and Z scroll buttons
One Touch "CALL" button
Built-in single-line LCD directory display
Programmable directory codes (1-4 digits)
10 and 11-digit dialing capability
Interfaces with 2 card readers - expandable to 16 with tracker expansion board(s)
Live transactions (requires RS-232 connection)
Anti-pass back
8000 event transaction buffer
31 Security (permission) levels
Database import/export capability
LED Lighted keypad
Built-in clock/calendar
Holiday schedule
Hold open time zones
Entry code time zones
Built-in postal lock provision

GENERAL SPECIFICATIONS

True Full Duplex Communication
Stores up to 3000 telephone numbers and names; memory sizes available: 125, 250, 500, 3000; specify requirement when ordering
Stores up to 255 area codes
Transaction buffer stores last 8000 events
Stores up to 8000 access card codes - dependent on system memory
31 security (permission) levels, 29 programmable with 4 time zones each
8 hold open time zones
Three anti-pass back configurations: passive, active and trap
Elevator control (note 1) for up to 4 elevators, each serving 64 floors
Expandable (note 2) to control up to 16 entry points
4-digit entry codes, one for each telephone number
3 form "C" dry contact relays
Single-line directory display uses super-twist LCD with 1/2-inch characters
EEPROM memory
Requires touch-tone, loop-start central office phone line
Two 16 VAC, 20 VA power transformers supplied
FCC (US): DUF6VT-12874-OT-T
DOC (CAN): 1736 4528 A
Compliant with UL 294. ETL listed
Dimensions Surface Mount: 13"H x 11.25"W x 4.75"D
Dimensions Flush Mount: 13.5"H x 12"W x 2.5"D
Dimensions Wall Mount: 15"H x 13.25"W x 3.5"D

DoorKing 1837 - PC Programmable

DoorKing 1837 - PC Programmable

Electronic Features

The Model 1837 is an ideal telephone entry and access control system suited for medium to large apartment and gated community applications as well as office buildings and industrial sites. The eight-line LCD display features big 1/2-inch characters for easy viewing and your personalized message appears on the screen when the system is not in use. Our unique "One Touch" CALL button makes this system one of the easiest to use on the market today! The built-in electronic directory, easy to use Remote Account Manager programming software, card reader interface and expandability options make this unit an ideal choice for those applications with a large number of system users and entry locations. Up to 16 card readers can be interfaced with the 1837 to provide access control. Additionally, our elevator control module restricts which floors a guest or system users have access to, making it an ideal system for high rise buildings. For additional security, the 1837 allows you to monitor activity AS IT HAPPENS on your computer display (requires RS-232 connection), and with our anti-pass back memory, you can enable a TRUE anti-pass back system in one of three different configurations; passive, active and trap.

The 1837 is available in three distinct styles: Surface mount, Flush mount and Wall mount.

PC Programmable via the internet (using DKS server connection), modem or RS-232. Remote Account Manager and Transaction Analysis software included
Large easy to use A and Z scroll buttons
One Touch "CALL" button
Built-in eight-line LCD directory display
Programmable directory codes (1-4 digits)
10 and 11-digit dialing capability
Interfaces with 2 card readers - expandable to 16 with tracker expansion board(s)
Live transactions (requires RS-232 connection)
Anti-pass back
8000 event transaction buffer
Elevator control - requires elevator control boards(s)
31 Security (permission) levels
Database import/export capability
LED Lighted keypad
Built-in clock/calendar
Holiday schedule
Hold open time zones
Entry code time zones
Built-in postal lock provision

GENERAL SPECIFICATIONS

True Full Duplex communication
Stores up to 3000 telephone numbers and names. Memory sizes available: 125, 250, 500, 3000. Specify requirement when ordering
Transaction buffer stores last 8000 events
Stores up to 8000 access card codes - dependent on system memory
31 security (permission) levels, 29 programmable with 4 time zones each
8 hold open time zones
Three anti-pass back configurations: passive, active and trap
Elevator control (note 1) for up to 4 elevators, each serving 64 floors
Expandable (note 2) to control up to 16 entry points
4-digit entry codes, one for each telephone number
3 form "C" dry contact relays
Eight-line directory display uses super-twist LCD with 1/2-inch characters
EEPROM memory
Requires touch-tone, loop-start central office phone line
16 VAC, 20 VA and 16 VAC, 50 VA power transformers supplied
FCC (US): DUF6VT-12874-OT-T
DOC (CAN): 1736 4528 A
Compliant with UL 294. ETL listed
Dimensions Surface Mount: 13"H x 11.25"W x 4.75"D
Dimensions Flush Mount: 13.5"H x 12"W x 2.5"D
Dimensions Wall Mount: 15"H x 13.25"W x 3.5"D

Elite Dial Code Telephone Entry for Perimeter Control

Elite Dial Code Telephone Entry for Perimeter Control

Electronic Features

The Dial Code LC and VF telephone entry/access control systems offer the latest technology for safe, convenient access in buildings with 25 to 1,000 tenants.

The bright, easy-to-read, 2-line screen includes a built-in resident directory for guests. Visitors can call and speak to any resident by simply entering the tenant's 3-digit personalized code. The tenant may then grant access by pressing a number on their telephone or deny access by simply hanging up.

Loaded with several standard and exclusive features, both Dial Code™ systems provide expandability to 31 remote locations, audio "help" assistance for guests and a patented "double box" design for easier installation and programming.

2-line large LCD or super-bright VF display
Two slots for memory cards
High-quality digital communication system with active noise filtering
History buffer up to 8,000 transactions
60 programmable utility keycodes per system
Field upgradable memory capacity
Programmable "unlisted resident" feature
6-digit resident keycode access
3-digit resident dialing
System mutes speaker during dialing
Touch-tone and rotary dial detection
User-friendly local programming via built-in keyboard
Two independent 7-day timers per relay ouput
Postal lock ready
3-year warranty

GENERAL SPECIFICATIONS

The Dial Code LC and VF telephone entry/access control systems offer the latest technology for safe, convenient access in buildings with 25 to 1,000 tenants.

Elite EL2000 Telephone Entry for Commercial Applications and Gated Communities

Elite EL2000 Telephone Entry for Commercial Applications and Gated Communities

Electronic Features

The EL2000 will change your expectations of what a telephone entry system should look like. The EL2000 is designed to complement virtually all gated community and is flexible enough to be used in apartment buildings, condo complexes, office parks and commercial sites.

The EL2000 features a 5-inch backlit LCD screen; the unit clearly displays up to 4 lines with 20 characters per line, making it a great choice for multi-tenant installations. The EL2000 is capable of accepting up to 2,000 totally flexible codes. These codes can be programmed as directory codes or access codes, making the EL2000 ideal for virtually any installation. Unlike other systems, the EL2000 may be purchased as a base unit or can be ordered with optional plug-in modules. This allows you to choose only the plug-in modules you need depending on the specifics of the job - enabling you to offer custom solutions right off the shelf without special orders.

Optional modules let you expand the system to fit your specific needs. The Wiegand output module lets you add card readers and/or remote keypads. Our RF module provides convenient access through gates or doors with Passport™ transmitters. Plus, the system is now designed to automatically detect the addition and location of each new plug-in module, making installation and programming faster and easier than ever before.

Universal board
Remote access diagnostics
E-Z scan
Voice prompts
Enhanced line noise tolerance
Legacy database conversion
Call waiting
Recessed, lighted, ADA-compliant keypad
Auto sensor input
Non-volatile memory
Daylight savings/leap year
Call button
Distinctive ringing
Entry codes
Holiday programming
Time zones
Anti-passback
Security lockout
Automatic gate/door unlock schedule
Transaction monitoring
Activity reports
Remote updates
Postal lock provision
1-year warranty

GENERAL SPECIFICATIONS

The EL2000 is designed to complement virtually all gated communities and is flexible enough to be used in apartment buildings, condo complexes, office parks and commercial sites.

Elite EL25 Residential and Commercial Telephone Entry System

Elite EL25 Residential and Commercial Telephone Entry System

Electronic Features

Elite EL25 Residential and Commercial Telephone Entry System with Expanded Capacity and Enhanced Versatility

The EL25 is beautifully engineered for private residences, yet fully adaptable for use in apartment buildings, condo complexes, office parks and commercial sites.

Unmatched in its class, the EL25 is designed to easily manage 2,000 FLEX-CODES. And unlike other systems, the EL25 can be purchased as a standard unit or with optional plug-in modules. This lets you choose only the plug-in modules you need depending on the specifics of the job, and allows you to offer custom solutions right off the shelf without special orders.

Available modules let you expand the system with complete control. An optional Wiegand module lets you add on card readers, prox readers and keypads to control up to four separate entrances around the property. An optional RF module provides convenient access through gates or doors with Passport™ transmitters.

Do not disturb
Call forwarding
Call waiting
Recessed, lighted, ADA-compliant keypad
Auto sensor input
Non-volatile memory
Daylight savings/leap year
Call button
Entry codes
Holiday programming
Time zones
Anti-passback
Security lockout
Automatic gate/door unlock schedule
Transaction monitoring
Activity reports
Remote updates
1-year warranty

GENERAL SPECIFICATIONS

The EL25 is beautifully engineered for private residences and gated communities, yet fully adaptable for use in apartment buildings, condo complexes, office parks and commercial sites.

Elite GAPLM Gate Access Panel

Elite GAPLM Gate Access Panel

Electronic Features

The Gate Access Panel has a fully functional access control keypad and the ability to communicate with an unlimited number of telephone interfaces, or wireless intercoms, in multiple configurations. This model also has a built-in 315MHz receiver to support handheld remote controls in both keyfob and visor configuration, making it the most complete entry access and communication device available.

Completely wireless
Up to 1,000-foot range (typically 300' - 700')
Up to 5 years of power with four C batteries
Secure digital encryption
Anti-tamper logic
Supports 16 remote controls
Master/Remote capable
Night-light on motion
50 user codes
6 "one-shot" codes: single-use codes for visitors
"Party" mode: holds gate open indefinitely for guests (with GCU)
Lockout mode: locks the system indefinitely for enhanced peace-of-mind and security
Pedestal or surface mount
Solar friendly
1-year warranty

GENERAL SPECIFICATIONS

The GAPLM provides wireless access and communication for single family residences, either at a gate or door. It is compatible with several of our wireless access and communication systems, all of which are customizable, easy to install, and easy to operate.

Elite ICON 26 Advanced Multi-Tenant Access Control System

Elite ICON 26 Advanced Multi-Tenant Access Control System

Electronic Features

The Icon26™ is a premium telephone entry/access control system for buildings with 250 to 1,000 tenants. Engineered to provide safe, convenient access for residents and guests, the system also offers added expandability and programming simplicity for isntallers and property managers.

Featuring a high-resolution, 10" LCD screen, the unit clearly displays up to 26 names at a time and is easily readable in all light conditions, including direct sunlight. This combined with its capability to operate in high temperatures (up to 165°F) makes this system an excellent choice for virutally any multi-tenant location.

The Icon 26™ also includes a long list of built-in and exclusive features such as a scrollable directory, optional camera capability, audio "help" assistance and a patented "double box" design for easier programming. Plus, the system is fully expandable to control up to 31 remote locations with 32 programmable user groups and 32 programmable 7-day timer templates.

High-resolution, 10", 26-name, large LCD
Two slots for memory cards
High-quality digital communication system
History buffer of up to 8,000 transactions
60 programmable utility keycodes per system
Field upgradable memory capacity
Programmable "unlisted resident" feature
6-digit resident keycode access
3-digit resident dialing
System mutes speaker during dialing
Touch-tone and rotary dial detection
User-friendly local programming via built-in keyboard
Two independent 7-day timers per relay output
Postal lock ready
"Exit Switch" ready
3-year warranty

GENERAL SPECIFICATIONS

The Icon26™ is a premium telephone entry/access control system for buildings with 250 to 1,000 tenants designed to provide safe, convenient access for residents and guests.

Residential Telephone Entry System Model RE-1N

Residential Telephone Entry System Model RE-1N

Electronic Features

The Model RE-1N Residential Telephone Entry System is designed for residential or light commercial access control applications. The speakerphone, keypad, radio receiver, and optional video camera are housed in a rugged enclosure that can be mounted to a pedestal or bolted directly to a wall. The diecast keypad keys have bright, easy-to-read graphics and are lit with an overhead light. The two operation buttons; CALL and HELP, are machined for heavy-duty reliability.

Arriving visitors will approach the unit and place a call to the residence by pressing the CALL button. The RE-1N will acquire the residence’s local telephone line and generate distinctive rings to the house telephones. The resident, knowing that the distinctive ring is originating from the access area, can answer any house telephone and converse with the visitor. If the resident decides to grant access to the visitor, they can activate either output relay in the RE-1N by pressing a key on the telephone’s keypad. If the resident decides not to grant access, hanging up or pressing a key will disconnect the visitor’s call.

If the resident is using the telephone at the time a visitor calls, the RE-1N will sound beeps on the telephone line to announce that a visitor is calling. The resident can press a key on the telephone to place the outside caller on hold and communicate with the visitor. After granting or denying access to the visitor, the outside caller will be re-connected to the resident.

Programmable call forwarding allows the RE-1N to dial any selected telephone number when a visitor presses the CALL button. For example, with call forwarding enabled, the RE-1N could dial a cell phone to contact the resident while outside or away from the residence. The resident will be able to communicate with the visitor and grant or deny access from the remote telephone.

For installations where multiple residences exist inside the same controlled opening (such as a guest house or granny flat) three alternate calling numbers can be programmed. The alternate numbers can be called by entering a short code at the keypad.

The resident can issue control commands from the local telephones without a call from a visitor. By dialing a specific series of digits, the resident can control either of the two relays. The resident an also initiate voice communications with the entry system.

Up to 100 entry codes, from 1 to 6 digits in length, can be programmed. Each entry code can activate either, or both, of the relay outputs. Linear’s Model AM-KP keypad can be used as a secondary remote keypad for the RE-1N.

Up to four sets of block coded MegaCode® transmitters (up to 60 transmitters total) can be used to gain access through the RE-1N’s built-in radio receiver. Each transmitter can be individually suspended or re-activated. Four facility codes can be programmed to identify each block of transmitters. Programming of individual (non-block coded) transmitters is not supported by the RE-1N.

The RE-1N contains an internal clock and calendar. Seven programmable time zones allow setting time periods to schedule system functions. Each time zone can be active or inactive on certain days. Keypad entry codes, wireless transmitters, automatic access control, call forwarding, and the Do Not Disturb feature can each be set to only be active during a specific time zone period. Up to ten holiday days can be programmed. Each of the seven time zones can be set to be active or inactive during a holiday.

The SENSE/INHIBIT input can be used two ways. If programmed for door sense, a switch on the door detects forced entry or door ajar situations. If programmed for inhibit, the input can be wired to a service switch or automatic timer that will disable the Relay #1 when required.

The OPEN REQUEST input can be wired to an exit loop detector or exit photo beam to allow automatic exit activation. An emergency access keyswitch can be mounted in the RE-1 case to allow keyed entry for authorized personnel.

The anti-passback feature allows the option of preventing the use of the same code or the same transmitter again before the programmed time elapses. The keypad lockout feature discourages tampering by disabling the keypad for three minutes after a programmable number of incorrect entry codes has been entered at the keypad.

An access log of up to 450 events is stored in the unit’s memory. System activity is logged as it occurs with the date and time of the event. The access log data can be retrieved locally or remotely with a computer through the RE-1N’s built-in modem.

The system’s built-in programming software can be accessed on-site or off-site using a computer with any Internet browser. The software’s graphic display of each of the programming step makes programming easy. Without a computer, the RE-1N can be programmed with its main keypad, from any local telephone connected to the same line, or by calling from any remote telephone.

The EEPROM memory retains all entry codes, transmitter information, and programming, even without power. Linear’s Model MGT safety edge transmitter is compatible with the RE-1N This MGT detects and transmits obstacle events to the RE-1N receiver. Obstacle signals from an MGT transmitter will activate Relay #2. Relay #2 can be programmed for alarm shunt to bypass an alarm loop during entry, or alarm trigger to cause an alarm during forced entry. Five other activation options are available for Relay #2. A built-in voice synthesizer sounds voice prompts through the speaker, local and remote telephones.

GENERAL SPECIFICATIONS

  • Dramatic Contemporary Styling
  • Cast Housing; Nickel finish
  • Downlighting
  • Voice Prompts, User Friendly, Owner Friendly
  • Two Programmable Outputs Control Two Openings
  • Obstacle Reverse, Alarm Shunt
  • Optional Low Light CCTV Camera Kit (Model RE-BWC1)
  • Provisions for Knox Box
  • Simple to Program and Maintain through On Board Keypad, Touchtone Telephone, or Computer with Modem
  • 450 Event Memory Log
  • Supports 100 Entry Codes
  • Supports 100 Block-Coded Transmitters
  • Applications include Single Residence, Commercial Sites, Employee Parking
  • Built-in superheterodyne radio receiver
  • MegaCode format
  • Operating Frequency: 318 MHz
  • Backup battery ready
  • 6.45" W x 10.81" H x 3.74" D
Residential Telephone Entry System Model RE-1SS

Residential Telephone Entry System Model RE-1SS

Electronic Features

The Model RE-1SS Residential Telephone Entry System is designed for residential or light commercial access control applications. The speakerphone, keypad, radio receiver, and optional video camera are housed in a rugged enclosure that can be mounted to a pedestal or bolted directly to a wall. The diecast keypad keys have bright, easy-to-read graphics and are lit with an overhead light. The two operation buttons; CALL and HELP, are machined for heavy-duty reliability.

Arriving visitors will approach the unit and place a call to the residence by pressing the CALL button. The RE-1SS will acquire the residence’s local telephone line and generate distinctive rings to the house telephones. The resident, knowing that the distinctive ring is originating from the access area, can answer any house telephone and converse with the visitor. If the resident decides to grant access to the visitor, they can activate either output relay in the RE-1SS by pressing a key on the telephone’s keypad. If the resident decides not to grant access, hanging up or pressing a key will disconnect the visitor’s call.

If the resident is using the telephone at the time a visitor calls, the RE-1SS will sound beeps on the telephone line to announce that a visitor is calling. The resident can press a key on the telephone to place the outside caller on hold and communicate with the visitor. After granting or denying access to the visitor, the outside caller will be re-connected to the resident.

Programmable call forwarding allows the RE-1SS to dial any selected telephone number when a visitor presses the CALL button. For example, with call forwarding enabled, the RE-1SS could dial a cell phone to contact the resident while outside or away from the residence. The resident will be able to communicate with the visitor and grant or deny access from the remote telephone.

For installations where multiple residences exist inside the same controlled opening (such as a guest house or granny flat) three alternate calling numbers can be programmed. The alternate numbers can be called by entering a short code at the keypad.

The resident can issue control commands from the local telephones without a call from a visitor. By dialing a specific series of digits, the resident can control either of the two relays. The resident an also initiate voice communications with the entry system.

Up to 100 entry codes, from 1 to 6 digits in length, can be programmed. Each entry code can activate either, or both, of the relay outputs. Linear’s Model AM-KP keypad can be used as a secondary remote keypad for the RE-1SS.

Up to four sets of block coded MegaCode® transmitters (up to 60 transmitters total) can be used to gain access through the RE-1SS’s built-in radio receiver. Each transmitter can be individually suspended or re-activated. Four facility codes can be programmed to identify each block of transmitters. Programming of individual (non-block coded) transmitters is not supported by the RE-1SS.

The RE-1SS contains an internal clock and calendar. Seven programmable time zones allow setting time periods to schedule system functions. Each time zone can be active or inactive on certain days. Keypad entry codes, wireless transmitters, automatic access control, call forwarding, and the Do Not Disturb feature can each be set to only be active during a specific time zone period. Up to ten holiday days can be programmed. Each of the seven time zones can be set to be active or inactive during a holiday.

The SENSE/INHIBIT input can be used two ways. If programmed for door sense, a switch on the door detects forced entry or door ajar situations. If programmed for inhibit, the input can be wired to a service switch or automatic timer that will disable the Relay #1 when required.

The OPEN REQUEST input can be wired to an exit loop detector or exit photo beam to allow automatic exit activation. An emergency access keyswitch can be mounted in the RE-1SS case to allow keyed entry for authorized personnel.

The anti-passback feature allows the option of preventing the use of the same code or the same transmitter again before the programmed time elapses. The keypad lockout feature discourages tampering by disabling the keypad for three minutes after a programmable number of incorrect entry codes has been entered at the keypad.

An access log of up to 450 events is stored in the unit’s memory. System activity is logged as it occurs with the date and time of the event. The access log data can be retrieved locally or remotely with a computer through the RE-1SS’s built-in modem.

The system’s built-in programming software can be accessed on-site or off-site using a computer with any Internet browser. The software’s graphic display of each of the programming step makes programming easy. Without a computer, the RE-1SS can be programmed with its main keypad, from any local telephone connected to the same line, or by calling from any remote telephone.

The EEPROM memory retains all entry codes, transmitter information, and programming, even without power. Linear’s Model MGT safety edge transmitter is compatible with the RE-1SS This MGT detects and transmits obstacle events to the RE-1SS receiver. Obstacle signals from an MGT transmitter will activate Relay #2. Relay #2 can be programmed for alarm shunt to bypass an alarm loop during entry, or alarm trigger to cause an alarm during forced entry. Five other activation options are available for Relay #2. A built-in voice synthesizer sounds voice prompts through the speaker, local and remote telephones.

GENERAL SPECIFICATIONS

  • Dramatic Contemporary Styling
  • Cast Housing; Stainless steel finish
  • Downlighting
  • Voice Prompts, User Friendly, Owner Friendly
  • Two Programmable Outputs Control Two Openings
  • Obstacle Reverse, Alarm Shunt
  • Optional Low Light CCTV Camera Kit (Model RE-BWC1)
  • Provisions for Knox Box
  • Simple to Program and Maintain through On Board Keypad, Touchtone Telephone, or Computer with Modem
  • 450 Event Memory Log
  • Supports 100 Entry Codes
  • Supports 100 Block-Coded Transmitters
  • Applications Include Single Residence, Commercial Sites, Employee Parking
  • Built-in superheterodyne radio receiver
  • MegaCode format
  • Operating Frequency: 318 MHz
  • Backup battery ready
  • 6.45" W x 10.81" H x 3.74" D
Residential Telephone Entry System Model RE-2N

Residential Telephone Entry System Model RE-2N

Electronic Features

The Model RE-2N Residential Telephone Entry System is designed for residential or light commercial access control applications. The speakerphone, keypad, radio receiver, and optional color video camera are housed in a rugged enclosure that can be mounted to a pedestal, bolted directly to a wall, or mounted recessed in a wall with the optional trim ring. The die-cast keypad keys have bright, easy-to-read graphics and are lit with overhead lights. The two operation buttons; CALL and HELP, are machined for heavy-duty reliability.

Operation:

Arriving visitors will approach the unit and place a call to the residence by pressing the CALL button. The RE-2N will acquire the residence’s local telephone line and generate distinctive rings to the house telephones. The resident, knowing that the distinctive ring is originating from the access area, can answer any house telephone and converse with the visitor. If the resident decides to grant access to the visitor, they can activate either output relay in the RE-2N by pressing a key on the telephone’s keypad. If the resident decides not to grant access, hanging up or pressing a key will disconnect the visitor’s call.

Call Waiting:

If the resident is using the telephone at the time a visitor calls, the RE-2N will sound beeps on the telephone line to announce that a visitor is calling. The resident can press a key on the telephone to place the outside caller on hold and communicate with the visitor. After granting or denying access to the visitor, the outside caller will be re-connected to the resident.

Call Forwarding:

Programmable call forwarding allows the RE-2N to dial any selected telephone number when a visitor presses the CALL button. For example, with call forwarding enabled, the RE-2N could dial a cell phone to contact the resident while outside or away from the residence. The resident will be able to communicate with the visitor and grant or deny access from the remote telephone.

Alternate Numbers:

For installations where multiple residences exist inside the same controlled opening (such as a guest house or granny flat) three alternate calling numbers can be programmed. The alternate numbers can be called by entering a short code at the keypad.

Local Control:

The resident can issue control commands from the local telephones without a call from a visitor. By dialing a specific series of digits, the resident can control either of the two relays. The resident an also initiate voice communications with the entry system.

Access Methods:

Up to 100 entry codes, from 1 to 6 digits in length, can be programmed. Each entry code can activate either, or both, of the relay outputs. Linear’s Model AM-KP keypad can be used as a secondary remote keypad for the RE-2N.

Up to 24 sets of block coded MegaCode® transmitters (up to 100 transmitters total) can be used to gain access through the RE-2N’s built-in radio receiver. Each transmitter can be individually suspended or re-activated. One facility codes can be programmed to identify each block of transmitters. Programming of individual (non-block coded) transmitters is not supported by the RE-2N.

System Features:

Time Zones:

The RE-2N contains an internal clock and calendar. Seven Programmable "time zones" allow setting time periods to schedule system functions. Each time zone can be active or inactive on certain days. Keypad entry codes, wireless transmitters, automatic access control, call forwarding, and the "Do Not Disturb" feature can each be set to only be active during a specific time zone period. Up to ten "holiday" days can be programmed. Each of the seven time zones can be set to be active or inactive during a holiday.

Portal Supervision:

The SENSE/INHIBIT input can be used two ways. If programmed for "door sense", a switch on the door detects forced entry or door ajar situations. If programmed for "inhibit", the input can be wired to a "service" switch or automatic timer that will disable the Relay #1 when required.

Hardwired Activation:

The OPEN REQUEST input can be wired to an exit loop detector or exit photo beam to allow automatic exit activation. An emergency access keyswitch can be mounted in the RE-2N case to allow keyed entry for authorized personnel.

Access Security:

The "anti-passback" feature allows the option of preventing the use of the same code or the same transmitter again before the programmed time elapses. The "keypad lockout" feature discourages tampering by disabling the keypad for three minutes after a programmable number of incorrect entry codes has been entered at the keypad.

Event Log:

An access log of up to 450 events is stored in the unit’s memory. System activity is logged as it occurs with the date and time of the event. The access log data can be retrieved locally or remotely with a computer through the RE-2N’s built-in modem.

Local & Remote Programming:

The system’s built-in programming software can be accessed on-site or off-site using a computer with any Internet browser. The software’s graphic display of each of the programming step makes programming easy. Without a computer, the RE-2N can be programmed with its main keypad, from any local telephone connected to the same line, or by calling from any remote telephone.

The EEPROM memory retains all entry codes, transmitter information, and programming, even without power.

Obstacle Detection:

Linear’s Model MGT safety edge transmitter is compatible with the RE-2N. This MGT detects and transmits obstacle events to the RE-2N receiver. Obstacle signals from an MGT transmitter will activate Relay #2.

Alarm Interface:

Relay #2 can be programmed for alarm shunt to bypass an alarm loop during entry, or alarm trigger to cause an alarm during forced entry. Five other activation options are available for Relay #2.

Voice Synthesizer:

A built-in voice synthesizer sounds voice prompts through the speaker, local and remote telephones.

GENERAL SPECIFICATIONS

  • Cast Housing; Nickel finish
  • Downlighting
  • Voice Prompts, User Friendly, Owner Friendly
  • Two Programmable Outputs Control Two Openings
  • Obstacle Reverse, Alarm Shunt
  • Optional Color CCTV Camera Kit (Model CCM-2)
  • Provisions for Knox Box
  • Simple to Program and Maintain through On Board Keypad, Touchtone Telephone, or Computer with Modem
  • 450 Event Memory Log
  • Supports 100 Entry Codes
  • Supports 100 Block-Coded Transmitters
  • Applications Include Single Residence, commercial Sites, Employee Parking
  • Built-in superheterodyne radio receiver
  • MegaCode format
  • Operating Frequency: 318 MHz
  • Backup battery ready
  • 10" W x 6-1/8" H x 4" D
Residential Telephone Entry System Model RE-2SS

Residential Telephone Entry System Model RE-2SS

Electronic Features

The Model RE-2SS Residential Telephone Entry System is designed for residential or light commercial access control applications. The speakerphone, keypad, radio receiver, and optional color video camera are housed in a rugged enclosure that can be mounted to a pedestal, bolted directly to a wall, or mounted recessed in a wall with the optional trim ring. The die-cast keypad keys have bright, easy-to-read graphics and are lit with overhead lights. The two operation buttons; CALL and HELP, are machined for heavy-duty reliability.

Operation:

Arriving visitors will approach the unit and place a call to the residence by pressing the CALL button. The RE-2SS will acquire the residence’s local telephone line and generate distinctive rings to the house telephones. The resident, knowing that the distinctive ring is originating from the access area, can answer any house telephone and converse with the visitor. If the resident decides to grant access to the visitor, they can activate either output relay in the RE-2SS by pressing a key on the telephone’s keypad. If the resident decides not to grant access, hanging up or pressing a key will disconnect the visitor’s call.

Call Waiting:

If the resident is using the telephone at the time a visitor calls, the RE-2SS will sound beeps on the telephone line to announce that a visitor is calling. The resident can press a key on the telephone to place the outside caller on hold and communicate with the visitor. After granting or denying access to the visitor, the outside caller will be re-connected to the resident.

Call Forwarding:

Programmable call forwarding allows the RE-2SS to dial any selected telephone number when a visitor presses the CALL button. For example, with call forwarding enabled, the RE-2SS could dial a cell phone to contact the resident while outside or away from the residence. The resident will be able to communicate with the visitor and grant or deny access from the remote telephone.

Alternate Numbers:

For installations where multiple residences exist inside the same controlled opening (such as a guest house or granny flat) three alternate calling numbers can be programmed. The alternate numbers can be called by entering a short code at the keypad.

Local Control:

The resident can issue control commands from the local telephones without a call from a visitor. By dialing a specific series of digits, the resident can control either of the two relays. The resident an also initiate voice communications with the entry system.

Access Methods:

Up to 100 entry codes, from 1 to 6 digits in length, can be programmed. Each entry code can activate either, or both, of the relay outputs. Linear’s Model AM-KP keypad can be used as a secondary remote keypad for the RE-2SS.

Up to 24 sets of block coded MegaCode® transmitters (up to 100 transmitters total) can be used to gain access through the RE-2SS’s built-in radio receiver. Each transmitter can be individually suspended or re-activated. One facility codes can be programmed to identify each block of transmitters. Programming of individual (non-block coded) transmitters is not supported by the RE-2SS.

System Features

Time Zones:

The RE-2SS contains an internal clock and calendar. Seven Programmable "time zones" allow setting time periods to schedule system functions. Each time zone can be active or inactive on certain days. Keypad entry codes, wireless transmitters, automatic access control, call forwarding, and the "Do Not Disturb" feature can each be set to only be active during a specific time zone period. Up to ten "holiday" days can be programmed. Each of the seven time zones can be set to be active or inactive during a holiday.

Portal Supervision:

The SENSE/INHIBIT input can be used two ways. If programmed for "door sense", a switch on the door detects forced entry or door ajar situations. If programmed for "inhibit", the input can be wired to a "service" switch or automatic timer that will disable the Relay #1 when required.

Hardwired Activation:

The OPEN REQUEST input can be wired to an exit loop detector or exit photo beam to allow automatic exit activation. An emergency access keyswitch can be mounted in the RE-2SS case to allow keyed entry for authorized personnel.

Access Security:

The "anti-passback" feature allows the option of preventing the use of the same code or the same transmitter again before the programmed time elapses. The "keypad lockout" feature discourages tampering by disabling the keypad for three minutes after a programmable number of incorrect entry codes has been entered at the keypad.

Event Log:

An access log of up to 450 events is stored in the unit’s memory. System activity is logged as it occurs with the date and time of the event. The access log data can be retrieved locally or remotely with a computer through the RE-2SS’s built-in modem.

Local & Remote Programming:

The system’s built-in programming software can be accessed on-site or off-site using a computer with any Internet browser. The software’s graphic display of each of the programming step makes programming easy. Without a computer, the RE-2SS can be programmed with its main keypad, from any local telephone connected to the same line, or by calling from any remote telephone.

The EEPROM memory retains all entry codes, transmitter information, and programming, even without power.

Obstacle Detection:

Linear’s Model MGT safety edge transmitter is compatible with the RE-2SS. This MGT detects and transmits obstacle events to the RE-2SS receiver. Obstacle signals from an MGT transmitter will activate Relay #2.

Alarm Interface:

Relay #2 can be programmed for alarm shunt to bypass an alarm loop during entry, or alarm trigger to cause an alarm during forced entry. Five other activation options are available for Relay #2.

Voice Synthesizer:

A built-in voice synthesizer sounds voice prompts through the speaker, local and remote telephones.

GENERAL SPECIFICATIONS

  • Cast Housing; Nickel finish
  • Downlighting
  • Voice Prompts, User Friendly, Owner Friendly
  • Two Programmable Outputs Control Two Openings
  • Obstacle Reverse, Alarm Shunt
  • Optional Color CCTV Camera Kit (Model CCM-2)
  • Provisions for Knox Box
  • Simple to Program and Maintain through On Board Keypad, Touchtone Telephone, or Computer with Modem
  • 450 Event Memory Log
  • Supports 100 Entry Codes
  • Supports 100 Block-Coded Transmitters
  • Applications Include Single Residence, commercial Sites, Employee Parking
  • Built-in superheterodyne radio receiver
  • MegaCode format
  • Operating Frequency: 318 MHz
  • Backup battery ready
  • 10" W x 6-1/8" H x 4" D

Featured Products